測定機 > ハンディオシロスコープ > HANTEK DSO8202E 携帯型オシロスコープ 200MHz帯域 
     
  前の商品 HANTEK DSO8202E 携帯型オシロスコープ 200MHz帯域 
 
 
HANTEK DSO8202E 携帯型オシロスコープ 200MHz帯域 

拡大 ( Size : 21 kb )
     
製造元 : hantek
原産地 : 中国
価格 : 105,980円(税込)
ショップポイント : 1,059
数量 :    残りあと1個
 
 
 
 
 
 
 
 
ハンディタイプで現場測定に最適なオシロスコープです。
Model DSO8072E DSO8102E DSO8152E DSO8202E
Bandwidth 70MHz 100MHz 150MHz 200MHz
Rise Time at BNC( typical) 5ns 3.5ns 2.3ns 1.8ns
Acquisition
Sample Modes Real-Time Sample
Acquisition Modes
Normal Normal data only
Peak Detect High-frequency and randon glith capture
Average Wavefom Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling AC, DC, GND
Inputs Impendance 1MΩ±2% ‖20pF±3pF
Probe Attenuation 1X, 10X
Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X
Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation Category;  CAT III: 150VRMS (1×)
Horizontal System
Sample Rate Range 1GS/s
Waveform Interpolation (sin x)/x
Record Length 2M
SEC/DIV Range 4ns/div~2000s/div, in a  2, 4, 8 sequence 2ns/div~2000s/div, in a  2, 4, 8 sequence
Sample Rate and Delay Time Accuracy ±50ppm over any ≥1ms time interval
Scanning Speed Range 4ns/div to 8ns/div; (-8div x s/div) to 40ms; 2ns/div to10ns/div;(-4div×s/div) to 20ms;
20ns/div to 80μs/div;(-8div×s/div) to 40ms;
200μs/div to 40s/div;(-8div×s/div) to 400s;
Delta Time Measurement Accuracy                 (Full Bandwidth) Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:
± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200
Vertical System
Vertical Resolution 8-bit resolution, all channel sampled simultaneously
Volts Range 2mV/div to 100V/div at input BNC
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled  ±400V(100V/div-20V/div);  ±50V(10V/div-5V/div); ±40V(2V/div-500mV/div);                                                                                                       ±2V(200mV/div-50mV/div); ±400mV(20mV/div-2mV/div);
Math +, -, *, /, FFT
FFT Windows:  Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point
Bandwidth Limit 20MHz
Low Frequency Response (-3db) ≤10Hz at BNC
DC Gain Accuracy ±3% for Normal or Average acquisition mode, 100V/div to 10mV/div.                                                                                                               ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div.
DC Measurement Accuracy, Average Acquisition Mode Measurement Type: Average of ≥16 waveforms with vertical position at zero
Accuracy: ± (3% × reading + 0.1div + 1mV) when 10mV/div or greater is selected.
Measurement Type: Average of ≥16 waveforms with vertical position not at zero
Accuracy: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div].
Volts Measurement Repeatability, Average Acquisition Mode Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source CH1, CH2, AC Line
Trigger Modes Auto, Normal, Single
Coupling Type DC, AC, HF Reject, LF Reject, Noise Reject
Trigger Sensitivity (Edge Trigger Type) DC(CH1,CH2): 1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
AC: Attenuates signals below 10Hz ; HF Reject: Attenuates signals above 80kHz;
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz.  
Trigger Level Range CH1/CH2: ±8 divisions from center of screen; 
Trigger Level Accuracy( typical)         Accuracy is for signals having                     rise and fall times 20ns CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
Set Level to 50%(typical) Operates with input signals ≥50Hz
Video Trigger
Video Trigger Type  CH1, CH2: Peak-to-peak amplitude of 2 divisions;
Signal Formats and Field Rates Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range 100ns ~ 10s
Pulse Width Trigger
Pulse Width Trigger Mode Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.     Not Equal: If the pulse is
 narrower than the specified width, the trigger point is the trailing edge. Otherwise,  the oscilloscope triggers when a pulse
 continues longer than the time specified as the Pulse Width.   Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer 
than the time specified as the Pulse Width
Pulse Width Range 20ns ~ 10s
Slope Trigger
Slope Trigger Mode Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range 20ns ~ 10s
Overtime Trigger
Over Time Modee Rising edge or Falling edge
Time Range 20ns ~ 10s
Alternative Trigger
Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution 6 digits
Accuracy (typical) ±30ppm (including all frequency reference errors and ±1 count errors)
Frequency Range AC coupled, from 4Hz minimum to rated bandwidth
Signal Source Pulse Width or Edge Trigger modes: all available trigger sources, The Frequency Counter measures trigger source at all times,
 including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single  shot event
 has completed.    Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s 
measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and
 the width is set to a relatively small time.     Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude
  and correct polarity.         Video Trigger mode: The Frequency Counter does not work.
Measure
Cursor Measurement  Manual: Voltage difference between cursors: V, Time difference between cursors: 
T Reciprocal of T in Hertz (1/ΔT);  Tracing: The valtage and time at a waveform point;
Auto Measuerment Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width,  -Pulse Width,
Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS,
Waveform Generator Mode
Frenquency Range 1Hz(DC)~25MHz
DAC Clock 2K~200MHz adjustable
Memory Depth 4KSa
Vertical Resolution 12 Bits
Stability <30ppm
Amplitude ±3.5V Max.
Output Impedance 50 Ω
Output Current 50mA Ipeak=50mA
System Bandwidth 25M
Harmonic Wave Distortion  -50dBc(1KHz),  -40dBc(10KHz)
General Specifications
Display Resolution 640 horizontal by 480 vertical pixels
Display Contrast Adjustable (16 gears) with the progress bar
Probe Compensator Output  
Output Voltage( typical) About 2Vpp into ≥1MΩ load
Frequency(typical) 1kHz
Power Supply
Supply Voltage AC Input:100-240VACRMS,0.6A MAX,50Hz~60Hz; DC Output:9V,2A
Power Consumption <30W
Environmental
Temperature Operating: 32 to 122 (0 to 50); Nonoperating: -40 to 159.8 (-40 to +71)
Cooling Method Convection
Humidity +104 or below (+40 or below): 90% relative humidity; 106 to 122 (+41 to 50): 60% relative humidity
Altitude Operating: Below 3,000m (10,000 feet); Nonoperaring: Below 15,000m(50,000 feet)
Mechanical
Size 260mmmm; 220mm; 75mm
Weight 2.5KG(without Packing)
DMM Modes
Max. Resolution 6000 Counts
DMM Testing Modes Voltage, Current, Resistance, Capacitance, Diode & Continuity
Max. Input Voltage AC:600V, DC: 800V
Max. Input Current AC: 10A, DC:10A
Input Impendance 10MΩ
Range Resolution Accuracy Resolution
DC Voltage 60.00mV ±1%±3 digit  10uV
600.0mV 100uV
6.000V 1mV
60.00V 10mV
600.0V 100mV
800V 1V
AC Voltage 60.00mV ±1%±3 digit 10uV
600.0mV 100uV
6.000V 1mV
60.00V 10mV
600.0V 100mV
DC Current 60.00mA ±1.5%±1 digit 10uA
600.0mA ±1.5%±5 digit  100uA
6.000A 1mA
10.00A 10mA
AC Current 60.00mA ±1%±5 digit  10uA
600.0mA ±1.5%±5 digit  100uA
6.000A 1mA
10.00A 10mA
Resistance 600 ±1%±3 digit 0.1Ω
6.000K
60.00K 10Ω
600.0K 1KΩ
6.000M 10KΩ
60.00M ±1%±5 digit  100KΩ
Capacitance 40.00nF ±2%±5 digit  10pF
400.0nF 100pF
4.000uF 1nF
40.00uF 10nF
400.0uF 100nF
Attention: the smallest capacitance value that can be measured in 5nF
Diode 0V~2.0V
ON-OFF test <10Ω